RSSG SS LQD
Housing:
316 Stainless Steel, Resin Encapsulated
Contacts:
2NO + 1NC (with door open)
Connection:
M12, 8-Pole
Coding:
Uniquely Coded, RFID
Indication:
Bi-Colour LED (Open/Close Indication)
Ingress Protection Rating:
IP67 and (IP69K: Pre-Wired Only)
RSSG-SS are standalone, non-contact RFID safety switches. With 2NO + 1NC contacts, capable of switching 500mA at 24Vdc. With tamper proof RFID switching, the RSSG-SS are suitable for use with safety relays with a low inrush current. A dual colour, built in LED helps the operator in speedy fault diagnosis. The RSSG-SS safety switches are available with an M12 leaded quick disconnect which are fully sealed and suitable for use in most wet / harsh environments
To view our animated video, please follow the link: RSSG-SS Video
| Nazwa | Numer referencyjny | Cena |
|---|---|---|
| 8-CORE-1KEYWAY-05M-QD | 356.073 | - |
| 8-CORE-1KEYWAY-10M-QD | 356.077 | - |
| RSSG-SS-21-DC-LQD | 364.031 | - |
| RSSG-SS-21-DC-LQD-05M | 364.032 | - |
| RSSG-SS-21-DC-LQD-10M | 364.033 | - |
| RSSG-SS-ACT | 364.034 | - |
| Specyfikacja techniczna | |
| Opcje napięcia zasilania | 24VDC |
| Pobór mocy | 2VA / 2W |
| Wyjście bezpieczne | 2 X NO |
| Ocena wyjścia bezpieczeństwa | 24Vdc/230Vac / 500mA |
| Wyjście AUX | 1 X NC |
| Ocena wyjścia AUX | 24Vdc/230Vac / 500mA |
| Przewód/złącze | M12 Quick Disconnect |
| Długość przewodu | 150mm |
| Kodowanie | RFID, Uniquely coded |
| Wskazanie | DUAL COLOUR LED |
| Wymiary jednostki sterującej (mm) | |
| Wymiary przełącznika (mm) | 88 X 25 X 20 |
| Wymiary siłownika (mm) | 88 X 25 X 20 |
| Klasa IP | SWITCH (IP69K) CONNECTOR (IP67) |
| Budowa | 316 Stainless Steel |
| Montaż | 4 x Śruby zabezpieczające M4 |
| Parametry środowiskowe | |
| Temperatura robocza | -25°C to +60°C |
| Temperatura przechowywania | -10°C to +60°C |
| Dane dotyczące bezpieczeństwa | |
| PL zgodnie z EN ISO 13849-1 | E |
| SIL CL zgodnie z EN IEC 62061 | 3 |
| PFHd zgodnie z EN IEC 62061 | 4.3 x 10-8 |
| PFH | 6.52 x 10-8 |
| B10d | 2,000,000 |
| MTTFd | High > 100 Years (Based on usage rate of 360 Days) |
| TM | > 20 lat |
| DC | 99% |
| SFF | 99% |
| Notes | |
1) Based on dual channel wiring according to CAT 4. Diagnostic coverage provided by downstream control logic. DC - medium, MTTFd = 100 Years |
|

(