| Number of inputs and outputs |
Number of digital outputs: 2 |
| Measuring range |
| 0...600 bar | 0...8700 psi | 0...60 MPa |
|
| Process connection |
threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
| Measuring element |
metallic thin film cell |
| Application |
for industrial applications |
| Media |
liquids and gases |
| Medium temperature |
-40...90 |
| Min. bursting pressure |
|
| Pressure rating |
|
| Note on pressure rating |
|
| Vacuum resistance |
|
| Type of pressure |
relative pressure |
| Operating voltage |
18...30 DC |
| Current consumption |
< 15 |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
< 0.3 |
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Total number of outputs |
2 |
| Output signal |
switching signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC |
2 |
| Permanent current rating of switching output DC |
100 |
| Switching frequency DC |
< 130 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Measuring range |
| 0...600 bar | 0...8700 psi | 0...60 MPa |
|
| Set point SP |
| 6...600 bar | 87...8702 psi | 0.6...60 MPa |
|
| Reset point rP |
| 3.1...597.1 bar | 44...8660 psi | 0.31...59.71 MPa |
|
| In steps of |
|
| Factory setting |
| SP1 = 150 bar | rP1 = 138 bar | ou1 = Hno; | | SP2 = 450 bar | rP2 = 438 bar | ou2 = Hno; | | dS1/dS2 = 0 ms | dr1/dr2 = 0 ms | | | coF = 0 % | P-n = PnP | dAP= 60 ms |
|
| Temperature monitoring |
|
| Measuring range |
|
| Set point SP |
| -38...90 °C | -36.4...194 °F |
|
| Reset point rP |
| -40...88 °C | -40...190.4 °F |
|
| In steps of |
|
| Switch point accuracy |
< ± 0,5 (nach DIN EN 61298-2) |
| Repeatability |
< ± 0,05; (with temperature fluctuations < 10 K) |
| Characteristics deviation |
< ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation |
< ± 0,1 (BFSL) / < ± 0,2 (LS) |
| Hysteresis deviation |
< ± 0,2 |
| Long-term stability |
< ± 0,1; (per 6 months) |
| Temperature coefficient zero point |
< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
| Temperature coefficient span |
< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C) |
| Temperature monitoring |
|
| Accuracy |
± 2 K + (0.1 x (ambient temperature - medium temperature)) |
| Notes on the accuracy / deviation |
temperature range -10 to 80 °C |
| Response time |
< 3 |
| Temperature monitoring |
|
| Dynamic response T05 / T09 |
< 80 / < 210 ( under ifm reference conditions ) |
| Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A) |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
5 |
| Process data binary |
2 |
| Min. process cycle time |
4.5 |
| IO-Link resolution pressure |
0.2 |
| IO-Link resolution temperature |
0.2 |
| IO-Link process data (cyclical) |
| function | bit length | | pressure | 16 | | temperature | 16 | | device status | 4 | | binary switching information | 2 |
|
| IO-Link functions (acyclical) |
application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter; Temperature peak counter |
| Supported DeviceIDs |
| Type of operation | DeviceID | | default | 1216 |
|
| Ambient temperature |
-40...90 |
| Storage temperature |
-40...100 |
| Protection |
IP 67; IP 69K |
| EMC |
|
| Shock resistance |
| DIN EN 60068-2-27 | 500 g (1 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
| UL approval |
| UL Approval no. | J038 | | File number UL | E174189 |
|
| Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight |
57 |
| Housing |
cylindrical |
| Dimensions |
Ø 19 / L = 66 |
| Materials |
stainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); PEI |
| Materials (wetted parts) |
stainless steel (303/1.4305); stainless steel (630/1.4542/17-4 PH) |
| Min. pressure cycles |
60 million; (at 1.2 times nominal pressure) |
| Tightening torque |
25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) |
| Process connection |
threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 |
| Process connection sealing |
FKM (DIN EN ISO 1179-2) |
| Restrictor element integrated |
yes |
| Remarks |
| BFSL = Best Fit Straight Line | | LS = limit value setting |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A |