Magnetic sensor LEC160
PRODUCENT CODE: -
CATEGORY: Incremental Linear Encoders | MagLine
Producer: SIKO GmbH
The product is available on request
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
At the moment, the product is not available in our warehouse.
After placing the order, we will notify you of the expected delivery date of the product.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
- Repeat accuracy max. ±1 μm
- Max. resolution 0.1 µm (LD output circuit)
- Reading distance 0.1 … 0.8 mm
- Works with MB160 magnetic tape
- Signal period 1600 μm
- Output circuit sin/cos or LD
- Function and status display LEDs
Technical data
Mechanical data | |
Weight | < 0.03 kg (without cable), cable 0.028 kg/m |
Housing | zinc die-cast |
Sensor/band reading distance | 0.1 … 0.8 mm (O, I reference signals) 0.1 … 0.5 mm (R reference signal) 0.4 … 0.6 mm (FR reference signal) |
Cable sheath | PUR, suitable for drag-chain use (8-core ø4.3-0.4 mm) |
Cable bending radius | 5x cable diameter (static) 10x cable diameter (dynamic) |
Electrical data | |
Ausgangsschaltung LD | |
Operating voltage | 5 V DC ±5 % |
Current consumption | < 50 mA (unloaded) < 120 mA (loaded) |
Status display | 2 LEDs (yellow, green) |
Output circuit | LD (RS422) |
Output signals | A, /A, B, /B, I, /I, R, /R, FR, /FR |
Output signal level high | >2.5 V |
Output signal level low | < 0.5 V |
Latency | 1.5 µs |
Pulse width of reference signal | 1, 2, 4 Increment(s) |
Type of connection | open cable end |
Ausgang Sin/Cos | |
Operating voltage | 5 V DC ±5 % |
Current consumption | < 35 mA (unloaded) < 50 mA (loaded) |
Status display | 2 LEDs (yellow, green) |
Output signals | sin, /sin, cos, /cos, index, /index |
Output voltage | 1 VPP ±10 % at 0 … 70 °C (120 Ω teminal resistance) |
Signal period | 1600 µm |
Offset voltage | UB/2 ±100 mV (sine/cosine mean to GND (5 V DC)) |
Phasing | 90°±1°, ±3° (20 kHz) (sin/cos) 45 ° (sin (reference signal)) 135 ° (cos (reference signal)) |
Pulse width of reference signal | 180°±40° |
Real-time requirement | speed-proportional signal output |
Type of connection | open cable end |
System data | |
Resolution | 0.1, 0.2, 0.5, 1, 2, 5, 10 µm (LD output circuit) |
Linearity deviation | ±3 µm |
Repeat accuracy | ±1 µm (0.3 mm reading distance) |
Measuring range | ∞ |
Travel speed | ≤25 m/s (sin/cos output, referencing speed ≤5 m/s) ≤25 m/s (LD output circuit, see table,referencing speed ≤5 m/s) |
Ambient conditions | |
Ambient temperature | -40 … 85 °C |
Storage temperature | -40 … 85 °C |
Relative humidity | 100 % (condensation admissible) |
EMC | EN 61326-1 (immunity requirement of industry) EN 61000-6-2 (class B emission limit) |
Protection category | IP60 (EN 60529) |
Shock resistance | ≤500 m/s2, 11 ms (EN 60068-2-27, half-sine, 3 axes (+/-), each 3 shocks) |
Vibration resistance | ≤100 m/s2, 10 Hz … 2000 Hz (EN 60068-2-6, 3 axes, each 10 cycles) |