Description
Wire-actuated encoder with redundant acquisition of linear measurement distances with a max. measuring length of4000 mm.
  • Robust design
  • Measuring lengths up to 4000 mm
  • Analogue signal output in redundant design (2x 4…20 mA or potentiometer)
  • Variable mounting options
  • Lockable vent and water drain holes
  • Very robust measuring rope (stainless steel)
  • IP65 protection class
  • M12 plug connection
Technical data
Mechanical data
Weight ~0.79 kg
Housing aluminum/plastic
Wire design ø0.87 mm (rustproof stainless steel, plastic-coated)
Extension force ≥8 N
Measured distance/ rope drum revolution 200 mm
Absolute accuracy ±0.35 % (relating to measuring length (mm))
Electrical data
Geber Potentiometer
Operating voltage ≤30 V DC (power loss on the potentiometer)
Power rating 2 W at 70 °C
Resistance 10 kΩ
5 kΩ
Resistance tolerance ±5 %
Standard terminal resistance 0.5 % or 1 Ω (the higher value always applies)
Linearity tolerance ±0.25 %
Type of connection M12 plug connector (A-coded) (8-pole, 1x pin)
Feature Technical Specifications (Enhancement)
Operating voltage 10 … 30 V DC (between I+ and I-, at ≤500 Ω load)
Output current 4   … 20 mA (2x) (4/20mA 4/20mA)
20 … 4 mA (2x) (20/4mA 20/4mA)
4 … 20 mA, 20 … 4 mA (4/20mA 20/4mA)
Type of connection M12 plug connector (A-coded) (8-pole, 1x pin)
* Transducers enable optimal adaptation of output current or output voltage to the measuring range. The measuring transformer is factory preset so that an output signal of 4 … 20 mA or 20 … 4 mA is available between the start and end points of the measuring range. * Transducers enable optimal adaptation of output current or output voltage to the measuring range. The measuring transformer is factory preset so that an output signal of 4 … 20 mA or 20 … 4 mA is available between the start and end points of the measuring range.
(* Transducers enable optimal adaptation of output current or output voltage to the measuring range. The measuring transformer is factory preset so that an output signal of 4 … 20 mA or 20 … 4 mA is available between the start and end points of the measuring range.
)
Messwandler, Stromausgang
Operating voltage 10 … 30 V DC (between I+ and I-, at ≤500 Ω load)
Output current 4   … 20 mA (2x) (4/20mA 4/20mA)
20 … 4 mA (2x) (20/4mA 20/4mA)
4 … 20 mA, 20 … 4 mA (4/20mA 20/4mA)
Type of connection M12 plug connector (A-coded) (8-pole, 1x pin)
Repeat accuracy ±0.25 mm (per direction of approach)
Travel speed ≤800 mm/s
Failure rate 166.7 Year(s) (at 60 °C (MTBF))
Ambient temperature -40 … 80 °C
Protection category IP65 (for electronic unit) (EN 60529, certonally coated electronics)
System data
Repeat accuracy ±0.25 mm (per direction of approach)
Travel speed ≤800 mm/s
Failure rate 166.7 Year(s) (at 60 °C (MTBF))
Ambient conditions
Ambient temperature -40 … 80 °C
Protection category IP65 (for electronic unit) (EN 60529, certonally coated electronics)