| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range |
|
| Communication interface |
IO-Link |
| Application |
asphalt; coated metal; liquids; glass; rubber; wood; ceramics; plastics; lacquers; food products; paper; fabric |
| Operating voltage |
18...32 DC; (to SELV/PELV) |
| Current consumption |
< 50 |
| Min. insulation resistance |
100; (50 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time |
< 1 |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Test input |
type 3 (IEC 61131-2) |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design |
PNP |
| Number of digital outputs |
1 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC |
2.5 |
| Permanent current rating of switching output DC |
150 |
| Number of analogue outputs |
1 |
| Analogue current output |
4...20 |
| Max. load |
500 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Short-circuit proof |
yes |
| Overload protection |
yes |
| Wave length range |
8...14 |
| Measuring range |
|
| Set point SP |
| -29...300 °C | -20.2...572 °F |
|
| Reset point rP |
| -30...299 °C | -22...570.2 °F |
|
| Analogue start point |
|
| Analogue end point |
|
| In steps of |
|
| Resolution |
|
| Resolution of switching output |
0.5 |
| Resolution of analogue output |
0.2; (+ 0.03% of the set measuring span) |
| Resolution of display |
0.5 |
| Accuracy |
< ± 1 %; (of measured value, min. 2 K (degree of emission = 1, T = 23 °C)) |
| Repeatability |
1 |
| Response time |
100 |
| Adjustment of the switch point |
programming buttons |
| Parameter setting options |
analogue range; normally open / normally closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
16 |
| Process data binary |
1 |
| Min. process cycle time |
3.6 |
| Supported DeviceIDs |
| Type of operation | DeviceID | | default | 716 |
|
| Ambient temperature |
0...65 |
| Storage temperature |
-20...80 |
| Max. relative air humidity |
95; (non condensing) |
| Protection |
IP 65 |
| EMC |
| DIN EN 61000-6-2 | | | DIN EN 61000-6-4 | |
|
| Shock resistance |
| DIN EN 60068-2-27 | 30 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 5 g (10...2000 Hz) |
|
| MTTF |
88.4 |
| Weight |
410.2 |
| Housing |
threaded type |
| Dimensions |
M30 x 1.5 / L = 189.5 |
| Thread designation |
M30 x 1.5 |
| Materials |
threaded sleeve: stainless steel (303/1.4305); polyester |
| Lens material |
| Infrared transparent crystal lens with anti-reflex coating |
|
| Display |
| Display unit | 2 x LED, yellow | | switching status | 1 x LED, yellow | | function display | 7-segment LED display, 4-digit | | measured values | 7-segment LED display, 4-digit |
|
| Operating elements |
|
| Items supplied |
|
| Remarks |
| Use a screened cable to protect infrared temperature sensors from interference. | | The screen must be connected to the housing of the sensor via the connector. |
|
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A |