Description
TA-025C2EM81-A-ZVG/US
- For use where space is restricted
- Very short response time
- Free 3-point calibration certificate available online
IO-Link features
- Precise analogue output and user-friendly communication via IO-Link
Technical data
Product characteristics | |||||
Number of inputs and outputs | Number of analogue outputs: 1 | ||||
Measuring range [°C] | -50...200 | ||||
Communication interface | IO-Link | ||||
Process connection | threaded connection G 1/8 internal thread | ||||
Installation length EL [mm] | 25 | ||||
Application | |||||
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) | ||||
Media | liquids and gases | ||||
Electrical data | |||||
Operating voltage [V] | 18...32 DC; ("supply class 2" to cULus) | ||||
Current consumption [mA] | < 50 | ||||
Protection class | III | ||||
Reverse polarity protection | yes | ||||
Power-on delay time [s] | 2 | ||||
Inputs / outputs | |||||
Number of inputs and outputs | Number of analogue outputs: 1 | ||||
Outputs | |||||
Total number of outputs | 1 | ||||
Output signal | analogue signal; IO-Link; (configurable) | ||||
Number of analogue outputs | 1 | ||||
Analogue current output [mA] | 4...20 | ||||
Max. load [Ω] | 250; ((18...19 V); 19...32 V: 300 Ω) | ||||
Short-circuit protection | yes | ||||
Overload protection | yes | ||||
Measuring/setting range | |||||
Measuring range [°C] | -50...200 | ||||
Factory setting | 0...200 °C | ||||
Resolution of analogue output [K] | 0.04 | ||||
Accuracy / deviations | |||||
Precision analogue output [K] | ± 0,3 + (± 0,1 % MS) | ||||
Temperature coefficient [% of the span / 10 K] | 0,1; (in case of deviation from the reference condition 25 ± 5 °C) | ||||
Response times | |||||
Dynamic response T05 / T09 [s] | < 0,25 / < 1 | ||||
Interfaces | |||||
Communication interface | IO-Link | ||||
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
Operating conditions | |||||
Ambient temperature [°C] | -25...80 | ||||
Note on ambient temperature |
|
||||
Storage temperature [°C] | -40...100 | ||||
Protection | IP 67; IP 68; IP 69K | ||||
Tests / approvals | |||||
EMC |
|
||||
Shock resistance |
|
||||
Vibration resistance |
|
||||
MTTF [years] | 334 | ||||
Mechanical data | |||||
Weight [g] | 92.8 | ||||
Housing | for adapter | ||||
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4122); PEI; FKM | ||||
Process connection | threaded connection G 1/8 internal thread | ||||
Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 | ||||
Probe diameter [mm] | 3 | ||||
Installation length EL [mm] | 25 | ||||
Displays / operating elements | |||||
Display |
|
||||
Remarks | |||||
Remarks |
|
||||
Pack quantity | 1 pcs. | ||||
Electrical connection | |||||
Connection | Connector: 1 x M12; coding: A |