Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range |
0...250 bar | 0...3625 psi | 0...25 MPa |
|
Process connection |
homogeniser connection |
Special feature |
Gold-plated contacts |
Measuring element |
diaphragm seal |
Application |
flush mountable for the food and beverage industry |
Media |
liquids and gases |
Medium temperature |
5...125; (150 maximum 1h) |
Min. bursting pressure |
|
Pressure rating |
|
Vacuum resistance |
|
Type of pressure |
relative pressure |
Operating voltage |
18...30 DC; (to SELV/PELV) |
Current consumption |
< 35 |
Min. insulation resistance |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time |
0.3 |
Integrated watchdog |
yes |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC |
2 |
Permanent current rating of switching output DC |
250 |
Switching frequency DC |
< 500 |
Number of analogue outputs |
1 |
Analogue current output |
4...20; (scalable 1:5) |
Max. load |
500 |
Analogue voltage output |
0...10; (scalable 1:5) |
Min. load resistance |
2000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring range |
0...250 bar | 0...3625 psi | 0...25 MPa |
|
Set point SP |
1.5...250 bar | 25...3625 psi | 0.15...25 MPa |
|
Reset point rP |
0.5...249 bar | 10...3610 psi | 0.05...24.9 MPa |
|
Analogue start point |
0...200 bar | 0...2900 psi | 0...20 MPa |
|
Analogue end point |
50...250 bar | 725...3625 psi | 5...25 MPa |
|
In steps of |
|
Switch point accuracy |
< ± 0,4; (Turn down 1:1) |
Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation |
< ± 1; (linearity, incl. hysteresis and repeatability; limit value setting to DIN EN IEC 62828-1) |
Hysteresis deviation |
< ± 0,1; (Turn down 1:1) |
Long-term stability |
< ± 0,05; (Turn down 1:1; per 6 months) |
Temperature coefficient zero point |
0,2; (5...80 °C) |
Temperature coefficient span |
0,2; (5...80 °C) |
Response time |
< 1.5 |
Delay time programmable dS, dr |
0...50 |
Damping process value dAP |
0...4 |
Damping for the analogue output dAA |
0...4 |
Max. response time analogue output |
3 |
Parameter setting options |
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
2 |
Min. process cycle time |
2.3 |
Supported DeviceIDs |
Type of operation | DeviceID | default | 460 |
|
Ambient temperature |
5...80 |
Storage temperature |
-40...100 |
Protection |
IP 67 |
EMC |
DIN EN 61000-6-2 | | DIN EN 61000-6-3 | |
|
Shock resistance |
DIN EN 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 | 10 g (10...2000 Hz) |
|
MTTF |
142 |
Weight |
1447 |
Housing |
cylindrical |
Dimensions |
Ø 34 / L = 197 |
Materials |
stainless steel (630/1.4542/17-4 PH); stainless steel (316L/1.4404); stainless steel (316L/1.4435); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) |
stainless steel (316L/1.4435) |
Min. pressure cycles |
60 million; (at 1.2 times nominal pressure) |
Process connection |
homogeniser connection |
Display |
Display unit | 3 x LED, green (bar, psi, MPa) | switching status | 2 x LED, yellow | measured values | alphanumeric display, red/green 4-digit |
|
Pack quantity |
1 pcs. |