| Output signal |
switching signal; IO-Link; (configurable) |
| Measuring range |
| 0...100 bar | 0...1450 psi | 0...10 MPa | |
| Process connection |
flange internal thread:G 1/4; internal thread:M6 |
| Special feature |
Gold-plated contacts |
| Design |
with flange adapter |
| Media |
liquids and gases |
| Conditionally suitable for |
use in gases at pressures &rt; 25 bar only on request |
| Medium temperature [°C] |
-25...80 |
| Min. bursting pressure |
|
| Pressure rating |
|
| Type of pressure |
relative pressure |
| Operating voltage [V] |
18...36 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] |
< 50 |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Overvoltage protection |
yes; (< 40 V) |
| Power-on delay time [s] |
0.3 |
| Integrated watchdog |
yes |
| Number of inputs and outputs |
Number of digital outputs: 2 |
| Total number of outputs |
2 |
| Output signal |
switching signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Switching frequency DC [Hz] |
< 170 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Measuring range |
| 0...100 bar | 0...1450 psi | 0...10 MPa | |
| Set point SP |
| 1...100 bar | 20...1450 psi | 0.1...10 MPa | |
| Reset point rP |
| 0.5...99.5 bar | 10...1440 psi | 0.05...9.95 MPa | |
| In steps of |
|
| Factory setting |
| SP1 = 25.0 bar | rP1 = 23.0 bar | | SP2 = 75.0 bar | rP2 = 73.0 bar | |
| Switch point accuracy [% of the span] |
< ± 0,5 |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] |
< ± 0,5; (linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Hysteresis deviation [% of the span] |
< ± 0,25 |
| Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] |
0,2; (-20...80 °C) |
| Temperature coefficient span [% of the span / 10 K] |
0,2; (-20...80 °C) |
| Delay time programmable dS, dr [s] |
0; 0,2...50 |
| Parameter setting options |
hysteresis / window; normally open / normally closed; diagnostic function; switching logic; switch-on/switch-off delay; Damping; Display unit |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 CDV |
| Profiles |
no profile |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
1 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
2.3 |
| Supported DeviceIDs |
| Type of operation | DeviceID | | Default | 309 | |
| Ambient temperature [°C] |
-20...80 |
| Storage temperature [°C] |
-40...100 |
| Protection |
IP 67 |
| EMC |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-5 Surge | 0,5/1 kV | | EN 61000-4-6 HF conducted | 10 V | |
| Shock resistance |
| DIN IEC 68-2-27 | 50 g (11 ms) | |
| Vibration resistance |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) | |
| MTTF [years] |
220 |
| Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Weight [g] |
381.5 |
| Materials |
stainless steel (1.4301 / 304); PC; PBT; PEI; FKM |
| Materials (wetted parts) |
steel (1.4104 / 430F); ceramics; FKM |
| Min. pressure cycles |
100 million |
| Process connection |
flange internal thread:G 1/4; internal thread:M6 |
| Restrictor element integrated |
no |
| Display |
| Display unit | 3 x LED, green | | switching status | 2 x LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit | |
| Pack quantity |
1 pcs. |