| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range |
| -0.05...0.4 bar | -50...400 mbar | -0.725...5.8 psi | -5...40 kPa |
|
| Process connection |
Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
| Special feature |
Gold-plated contacts |
| Measuring element |
ceramic-capacitive pressure measuring cell |
| Temperature monitoring |
no |
| Application |
flush mountable for the food and beverage industry |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature |
-25...150 |
| Min. bursting pressure |
| 30000 mbar | 435 psi | 3000 kPa |
|
| Pressure rating |
|
| Note on pressure rating |
| take into account the pressure resistance of the bracket and the seal used for clamp connection |
|
| Vacuum resistance |
|
| Type of pressure |
relative pressure |
| No dead space |
yes |
| Operating voltage |
18...30 DC |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Measuring principle |
hydrostatic |
| Integrated watchdog |
yes |
| 2-wire |
|
| Current consumption |
3.5...21.5 |
| Power-on delay time |
1 |
| 3-wire |
|
| Current consumption |
< 45 |
| Power-on delay time |
0.5 |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Total number of outputs |
2 |
| Output signal |
analogue signal; IO-Link; (configurable) |
| Number of digital outputs |
1; (IO-Link) |
| Number of analogue outputs |
1 |
| Analogue current output |
4...20; (scalable) |
| Max. load |
700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA) |
| Short-circuit proof |
yes |
| Overload protection |
yes |
| Measuring range |
| -0.05...0.4 bar | -50...400 mbar | -0.725...5.8 psi | -5...40 kPa |
|
| Analogue start point |
| -50...320 mbar | -0.725...4.641 psi | -5...32 kPa |
|
| Analogue end point |
| 30...400 mbar | 0.435...5.802 psi | 3...40 kPa |
|
| In steps of |
| 0.1 mbar | 0.001 psi | 0.01 kPa |
|
| Factory setting |
| ASP = 0.0 mbar | AEP = 400 mbar | |
|
| Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation |
< ± 0,2 (DIN EN 61298-2); (incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1) |
| Linearity deviation |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation |
< ± 0,15; (Turn down 1:1) |
| Long-term stability |
< ± 0,1; (Turn down 1:1; per year) |
| Total deviation over temperature range |
| Temperature range | total deviation | | -25...15 °C | Characteristics deviation ± 0,1 % of the span / 10 K | | 15...80 °C | Characteristics deviation | | 80...150 °C | Characteristics deviation ± 0,15 % of the span / 10 K |
|
| Notes on the accuracy / deviation |
for further details see section Diagrams and graphs |
| Damping for the analogue output dAA |
0...4 |
| 2-wire |
|
| Step response time analogue output |
30 |
| 3-wire |
|
| Step response time analogue output |
7 |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| Profiles |
Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
| SIO mode |
no |
| Required master port type |
A |
| Process data analogue |
3 |
| Min. process cycle time |
3.2 |
| Supported DeviceIDs |
| Type of operation | DeviceID | | default | 1410 |
|
| Ambient temperature |
-25...80 |
| Storage temperature |
-40...100 |
| Protection |
IP 67; IP 68; IP 69K |
| EMC |
| DIN EN 61000-6-2 | | | DIN EN 61000-6-3 | |
|
| Shock resistance |
| DIN EN 60068-2-27 | 50 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
| MTTF |
323 |
| Note on approval |
| factory certificate available as download at www.factory-certificate.ifm |
|
| UL approval |
| UL Approval no. | J055 | | File number UL | E174189 |
|
| Weight |
392.4 |
| Housing |
cylindrical |
| Dimensions |
Ø 30.2 / L = 111.4 |
| Materials |
stainless steel (316L/1.4404); PBT |
| Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (316L/1.4435); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
| Min. pressure cycles |
100 million |
| Process connection |
Clamp DN25...DN40 (1...1,5") DIN 32676 (ISO 2852) |
| Display unit |
mbar; psi; kPa; mmWS; inH2O |
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |