| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range |
| -1...16 bar | -14.5...232 psi | -0.1...1.6 MPa |
|
| Process connection |
threaded connection G 1/2 external thread |
| Special feature |
Gold-plated contacts |
| Measuring element |
ceramic-capacitive pressure measuring cell |
| Temperature monitoring |
yes |
| Application |
flush mountable for industrial applications; for industrial applications |
| Media |
viscous media and liquids with suspended particles; Liquids; other media on request |
| Medium temperature |
-25...110; (flush mount zero-leak using metal-to-metal seal. for permissible temperatures of other sealing versions, see sealing materials under "Accessories") |
| Min. bursting pressure |
|
| Pressure rating |
|
| Vacuum resistance |
-1000 |
| Type of pressure |
relative pressure; vacuum |
| No dead space |
yes |
| Operating voltage |
9.6...30 DC |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Integrated watchdog |
yes |
| 2-wire |
|
| Current consumption |
3.5...21.5 |
| Power-on delay time |
< 1 |
| 3-wire |
|
| Current consumption |
< 30 |
| Power-on delay time |
< 0.5 |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Total number of outputs |
2 |
| Output signal |
analogue signal; IO-Link |
| Number of digital outputs |
1; (IO-Link) |
| Number of analogue outputs |
1 |
| Analogue current output |
4...20; (scalable; 1:5) |
| Max. load |
(Ub - 9,6 V) / 21,5 mA; 670 Ω (Ub = 24 V) |
| Short-circuit proof |
yes |
| Overload protection |
yes |
| Measuring range |
| -1...16 bar | -14.5...232 psi | -0.1...1.6 MPa |
|
| Analogue start point |
| -1...14 bar | -14.5...203.1 psi | -0.1...1.4 MPa |
|
| Analogue end point |
| 1...16 bar | 14.5...232.1 psi | 0.1...1.6 MPa |
|
| In steps of |
| 0.002 bar | 0.2 psi | 0.0002 MPa |
|
| Factory setting |
| ASP = 0.0 bar | AEP = 16.0 bar | | | ASP = 0.0 psi | AEP = 232.1 psi | | | ASP = 0.0 MPa | AEP = 1.6 MPa | |
|
| Temperature monitoring |
|
| Measuring range |
|
| Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation |
< ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation |
< ± 0,15; (Turn down 1:1) |
| Long-term stability |
< ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point |
< ± 0,1 (-25...85 °C) < ± 0,3 (85...110 °C) |
| Temperature coefficient span |
< ± 0,1 (-25...85 °C) < ± 0,3 (85...110 °C) |
| Temperature monitoring |
|
| Accuracy |
± 2.5 K + (0.045 x (ambient temperature - medium temperature)) |
| Damping process value dAP |
0...99.99 |
| Damping for the analogue output dAA |
0...99.99 |
| 2-wire |
|
| Step response time analogue output |
12 |
| 3-wire |
|
| Step response time analogue output |
3 |
| Temperature monitoring |
|
| Dynamic response T05 / T09 |
< 10 / < 25; (DIN EN 60751 water; > 0,9 m/s) |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor ED2: Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A) |
| SIO mode |
no |
| Required master port type |
A; (when pin 2 not connected: B) |
| Min. process cycle time |
3.5 |
| IO-Link resolution pressure |
0.002 |
| IO-Link resolution temperature |
0.2 |
| IO-Link process data (cyclical) |
| function | bit length | | pressure | 16 | | temperature | 16 | | device status | 4 |
|
| IO-Link functions (acyclical) |
application specific tag; internal temperature |
| Supported DeviceIDs |
| Type of operation | DeviceID | | default | 1490 |
|
| Ambient temperature |
-25...90 |
| Storage temperature |
-40...100 |
| Protection |
IP 67; IP 68; IP 69 |
| EMC |
|
| Shock resistance |
| DIN EN 60068-2-27 | 50 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
| MTTF |
427 |
| Embedded software included |
yes |
| UL approval |
| Enclosure type | Type 1 | | UL Approval no. | J050 | | File number UL | E174189 |
|
| Weight |
114 |
| Housing |
cylindrical |
| Dimensions |
Ø 30 / L = 63 |
| Materials |
stainless steel (316L/1.4435); stainless steel (316L/1.4404); PA; PTFE; FKM |
| Materials (wetted parts) |
stainless steel (316L/1.4435); Al2O3 (ceramics); surface characteristics : Ra < 0,4 / Rz 4; PTFE; (FKM for sealing with seal DIN EN ISO 1179-2, see operating instructions) |
| Min. pressure cycles |
100 million |
| Tightening torque |
25 |
| Process connection |
threaded connection G 1/2 external thread |
| Display |
| operating status | 2 LED, green |
|
| Items supplied |
| Gasket: G1/2, FKM DIN EN ISO1179-2 (-15...110°C), E30492 |
|
| Accessories (optional) |
| Gasket: G1/2, FKM DIN EN ISO1179-2 (-15...110°C), E30492 | | Gasket: G1/2, EPDM DIN EN ISO1179-2 (-25...110°C), E30451 | | Gasket: G1/2, FFKM DIN EN ISO1179-2 (-5...110°C), E30513 | | O-ring: 16,4 x 1, FKM (-15...110°C), E30510 | | O-ring: 16,4 x 1, EPDM (-25...110°C), E30511 | | O-ring: 16,4 x 1, FFKM (-5...110°C), E30512 |
|
| Pack quantity |
1 pcs. |
| Connection |