| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range |
| -0.0124...0.25 bar | -12.4...250 mbar | -5...100.4 inH2O | -1.24...25 kPa |
|
| Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
| Special feature |
Gold-plated contacts |
| Application |
flush mountable for the food and beverage industry |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C] |
-25...125; (145 max. 1h) |
| Min. bursting pressure |
| 30000 mbar | 12044 inH2O | 3000 kPa |
|
| Pressure rating |
| 6000 mbar | 2400 inH2O | 600 kPa |
|
| Vacuum resistance [mbar] |
-1000 |
| Type of pressure |
relative pressure |
| No dead space |
yes |
| MAWP (for applications according to CRN) [bar] |
10 |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Measuring principle |
hydrostatic |
| Integrated watchdog |
yes |
| Operating voltage [V] |
20...32 DC |
| Current consumption [mA] |
3.6...21 |
| Power-on delay time [s] |
1 |
| Operating voltage [V] |
18...32 DC |
| Current consumption [mA] |
< 45 |
| Power-on delay time [s] |
0.5 |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4...20, invertible; (scalable) |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Max. load [Ω] |
300 |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Switching frequency DC [Hz] |
125 |
| Max. load [Ω] |
(Ub - 10 V) / 20 mA |
| Measuring range |
| -0.0124...0.25 bar | -12.4...250 mbar | -5...100.4 inH2O | -1.24...25 kPa |
|
| Set point SP |
| -12...250 mbar | -4.8...100.4 inH2O | -1.2...25 kPa |
|
| Reset point rP |
| -12.4...249.6 mbar | -5...100.2 inH2O | -1.24...24.96 kPa |
|
| Analogue start point |
| -12.4...187.4 mbar | -5...75.2 inH2O | -1.24...18.74 kPa |
|
| Analogue end point |
| 50...250 mbar | 20.1...100.4 inH2O | 5...25 kPa |
|
| In steps of |
| 0.2 mbar | 0.1 inH2O | 0.02 kPa |
|
| Factory setting |
| | SP1 = 62.4 mbar | rP1 = 57.4 mbar | | | SP2 = 187.4 mbar | rP2 = 182.4 mbar | | | ASP = 0.0 mbar | AEP = 250.0 mbar |
|
| Switch point accuracy [% of the span] |
< ± 0,2; (Turn down 1:1) |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] |
< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
| Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,05; (0...70 °C) |
| Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0...70 °C) |
| Damping process value dAP [s] |
0...30 |
| Damping for the analogue output dAA [s] |
0.01...99.99 |
| Step response time analogue output [ms] |
45 |
| Min. response time of switching output (dAP) [ms] |
3 |
| Step response time analogue output [ms] |
7 |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.0 |
| Profiles |
no profile |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
1 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
2.3 |
| Supported DeviceIDs |
| Type of operation | DeviceID |
|---|
| default | 257 |
|
| Ambient temperature [°C] |
-25...80 |
| Storage temperature [°C] |
-40...100 |
| Protection |
IP 67; IP 68; IP 69K |
| EMC |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-5 Surge | 0,5/1 kV | | EN 61000-4-6 HF conducted | 10 V |
|
| Shock resistance |
| DIN IEC 68-2-27 | 50 g (11 ms) |
|
| Vibration resistance |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
|
| MTTF [years] |
160 |
| Note on approval |
| factory certificate available as download at www.factory-certificate.ifm |
|
| UL approval |
| UL Approval no. | J018 | | File number UL | E174189 |
|
| Weight [g] |
354 |
| Materials |
stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
| Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
| Min. pressure cycles |
100 million |
| Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
| Display |
| Display unit | LED, green | | switching status | LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Display unit |
mbar; kPa; inH2O; mmWS; % of the span |
| Pack quantity |
1 pcs. |
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |