| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range |
| -50...1000 mbar | -0.73...14.5 psi | -5...100 kPa |
|
| Process connection |
Clamp DN50 (2") DIN 32676 (ISO 2852) |
| Special feature |
Gold-plated contacts |
| Application |
flush mountable for the food and beverage industry |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature |
-20...200; (-20...90 < 0 bar) |
| Min. bursting pressure |
| 30000 mbar | 435 psi | 3000 kPa |
|
| Pressure rating |
| 10000 mbar | 145 psi | 1000 kPa |
|
| Type of pressure |
relative pressure |
| Min. insulation resistance |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Integrated watchdog |
yes |
| 2-wire |
|
| Operating voltage |
20...32 DC |
| Current consumption |
3.6...21 |
| Power-on delay time |
1 |
| 3-wire |
|
| Operating voltage |
18...32 DC |
| Current consumption |
< 45 |
| Power-on delay time |
0.5 |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Number of analogue outputs |
1 |
| Analogue current output |
4...20, invertible; (scalable) |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| 2-wire |
|
| Max. load |
300 |
| 3-wire |
|
| Max. voltage drop switching output DC |
2 |
| Permanent current rating of switching output DC |
250 |
| Switching frequency DC |
125 |
| Max. load |
(Ub - 10 V) / 20 mA |
| Measuring range |
| -50...1000 mbar | -0.73...14.5 psi | -5...100 kPa |
|
| Set point SP |
| -48...1000 mbar | -0.7...14.5 psi | -4.8...100 kPa |
|
| Reset point rP |
| -50...998 mbar | -0.73...14.47 psi | -0.5...99.8 kPa |
|
| Analogue start point |
| -50...750 mbar | -0.73...10.88 psi | -5...75 kPa |
|
| Analogue end point |
| 200...1000 mbar | 2.9...14.5 psi | 20...100 kPa |
|
| In steps of |
|
| Factory setting |
| SP1 = 250 mbar | rP1 = 230 mbar | | SP2 = 750 mbar | rP2 = 730 mbar | | ASP = 0 mbar | AEP = 1000 mbar |
|
| Switch point accuracy |
< ± 0,2; (Turn down 1:1) |
| Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation |
< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation |
< ± 0,15; (Turn down 1:1) |
| Hysteresis deviation |
< ± 0,15; (Turn down 1:1) |
| Long-term stability |
< ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point |
< ± 0,3; (0...200 °C) |
| Temperature coefficient span |
< ± 0,15; (0...200 °C) |
| Damping process value dAP |
0...30 |
| Damping for the analogue output dAA |
0.01...99.99 |
| 2-wire |
|
| Step response time analogue output |
45 |
| 3-wire |
|
| Min. response time of switching output (dAP) |
3 |
| Step response time analogue output |
7 |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.0 |
| SDCI standard |
IO-Link Communication Specification, Version 1.0, January 2009, Ordner No: 10.002 |
| Profiles |
no profile |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
1 |
| Process data binary |
2 |
| Min. process cycle time |
2.3 |
| Supported DeviceIDs |
| Type of operation | DeviceID | | default | 106 |
|
| Ambient temperature |
-25...80 |
| Note on ambient temperature |
| Medium temperature: ≤ 160 °C |
|
| Ambient temperature |
-25...65 |
| Note on ambient temperature |
| Medium temperature: ≤ 200 °C |
|
| Storage temperature |
-25...100 |
| Protection |
IP 67; IP 68; IP 69K |
| EMC |
| DIN EN 61000-6-2 | | | DIN EN 61000-6-3 | |
|
| Shock resistance |
| DIN EN 60068-2-27 | 50 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 | 20 g (10...2000 Hz) |
|
| MTTF |
142 |
| Note on approval |
| Including free 6-point calibration certificate. |
|
| Weight |
1200.45 |
| Housing |
cylindrical |
| Dimensions |
Ø 50 / L = 163 |
| Materials |
stainless steel (316L/1.4404); stainless steel (316L/1.4435); PBT; PEI; PFA |
| Materials (wetted parts) |
stainless steel (316L/1.4435) |
| Min. pressure cycles |
10 million |
| Process connection |
Clamp DN50 (2") DIN 32676 (ISO 2852) |
| Surface characteristics Ra/Rz of the wetted parts |
< 0.38 / - |
| Fill fluid for pressure transmission |
NEOBEE (food grade, FDA compliant) |
| Diaphragm diameter |
47.5 |
| Display |
| Display unit | LED, green | | switching status | LED, yellow | | function display | alphanumeric display, 4-digit | | measured values | alphanumeric display, 4-digit |
|
| Display unit |
mbar; kPa; psi; inH2O; mWS; % of the span |
| Pack quantity |
1 pcs. |