Description
PI-160-REA01-MFRKG/US/ /P
Technical data
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0...160 bar0...2320 psi0...16 MPa
Process connection threaded connection G 1 external thread sealing cone
Application
Special feature Gold-plated contacts
Application flush mountable for the food and beverage industry
Media viscous media and liquids with suspended particles; liquids and gases; use in gases at pressures > 25 bar only on request
Medium temperature -25...150
Min. bursting pressure
650 bar9425 psi65 MPa
Pressure rating
200 bar2900 psi20 MPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressure relative pressure; vacuum
No dead space yes
Electrical data
Min. insulation resistance 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Integrated watchdog yes
2-wire
Operating voltage 20...30 DC
Current consumption 3.5...21.5
Power-on delay time < 1
3-wire
Operating voltage 18...30 DC
Current consumption 5...45; (430 bei max. Laststrom)
Power-on delay time < 0.5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; IO-Link
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output 4...20, invertible; (scalable)
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
2-wire
Max. load 300
3-wire
Max. voltage drop switching output DC 2
Permanent current rating of switching output DC 100
Switching frequency DC 125
Max. load (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V)
Measuring/setting range
Measuring range
0...160 bar0...2320 psi0...16 MPa
Set point SP
0.2...160 bar3...2321 psi0.02...16 MPa
Reset point rP
0...159.8 bar0...2317 psi0...15.98 MPa
Analogue start point
0...128 bar0...1856 psi0...12.8 MPa
Analogue end point
32...160 bar464...2321 psi3.2...16 MPa
Min. difference between SP and rP
0.2 bar3 psi0.02 MPa
In steps of
0.1 bar1 psi0.01 MPa
Factory setting
SP1 = 40 barrP1 = 36.8 bar
SP2 = 120 barrP2 = 116.8 bar
ASP = 0.00 barAEP = 160 bar
dAP = 0.06 sdAA = 0.06 s
Temperature monitoring
Measuring range
-25...150 °C-13...302 °F
Accuracy / deviations
Switch point accuracy < ± 0,5; (DIN EN IEC 62828-1; Turn down 1:1)
Repeatability < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation < ± 0,5; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation < ± 0,15; (Turn down 1:1)
Zero-point stabilisation
IO-Link, analogue output0,15; (see operating instructions zero-point behaviour)
display, switching output0,2
Hysteresis deviation < ± 0,15; (Turn down 1:1)
Long-term stability < ± 0,1; (Turn down 1:1; per year)
Total deviation over temperature range
Temperature rangetotal deviation
-25...15 °CCharacteristics deviation ± 0,15 % of the span / 10 K
15...80 °CCharacteristics deviation
80...150 °CCharacteristics deviation ± 0,2 % of the span / 10 K
Notes on the accuracy / deviation for further details see section Diagrams and graphs
Temperature monitoring
Accuracy ± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability ± 0,2
Resolution 0.2
Response times
Damping process value dAP 0...99.99
Damping for the analogue output dAA 0...99.99
2-wire
Step response time analogue output 30
3-wire
Min. response time of switching output (dAP) 3
Step response time analogue output 7
Temperature monitoring
Dynamic response T05 / T09 < 35 / < 135; (DIN EN 60751 water ; > 0,9 m/s)
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO mode yes
Required master port type A
Min. process cycle time 5.6
IO-Link resolution pressure 0.005
IO-Link resolution temperature 0.2
IO-Link process data (cyclical)
functionbit length
pressure32
temperature32
device status4
binary switching information2
IO-Link functions (acyclical) application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter; measuring cell diagnosis
Supported DeviceIDs
Type of operationDeviceID
default1825
Operating conditions
Ambient temperature -25...80
Storage temperature -40...100
Protection IP 67; IP 68; IP 69K
Tests / approvals
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF 201
UL approval
UL Approval no.J034
Mechanical data
Weight 406.438
Housing cylindrical
Dimensions Ø 50 / L = 116
Materials Housing: stainless steel (316L/1.4404); pushbuttons: PBT; sealings: FKM; M12 connector: PEI; Display: PFA
Materials (wetted parts) measuring cell: ceramics (99.9 % Al2O3); Process connection: stainless steel (316L/1.4435) surface characteristics Ra < 0,4 / Rz 4; Sealing: PTFE
Min. pressure cycles 100 million
Tightening torque 20
Process connection threaded connection G 1 external thread sealing cone
Displays / operating elements
Display
Display unitLED, green
switching statusLED, yellow
function displayalphanumeric display, 4-digit
measured valuesalphanumeric display, 4-digit
Display unit bar; psi; MPa
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated