Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Measuring range |
-1...1 bar | -1000...1000 mbar | -14.52...14.52 psi |
|
Process connection |
threaded connection G 1/2 external thread |
Special feature |
Gold-plated contacts |
Application |
for industrial applications |
Media |
liquids and gases |
Medium temperature |
-25...80 |
Min. bursting pressure |
|
Pressure rating |
|
Type of pressure |
relative pressure; vacuum |
Operating voltage |
18...32 DC |
Current consumption |
< 70; (24 V) |
Min. insulation resistance |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time |
6 |
Integrated watchdog |
yes |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC |
2 |
Permanent current rating of switching output DC |
250 |
Switching frequency DC |
75 |
Number of analogue outputs |
1 |
Analogue current output |
4...20, invertible; (scalable) |
Max. load |
(Ub - 10 V) / 20 mA |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Measuring range |
-1...1 bar | -1000...1000 mbar | -14.52...14.52 psi |
|
Set point SP |
-0.992...1.6 bar | -14.4...23.22 psi |
|
Reset point rP |
-1...1.592 bar | -14.52...23.1 psi |
|
Analogue start point |
-1...1.1 bar | -14.52...15.96 psi |
|
Analogue end point |
-0.5...1.6 bar | -7.26...23.22 psi |
|
In steps of |
|
Switch point accuracy |
< ± 0,5; (Turn down 1:1) |
Repeatability |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line) |
Hysteresis deviation |
< ± 0,25; (Turn down 1:1) |
Long-term stability |
< ± 0,1; (Turn down 1:1; per 6 months) |
Temperature coefficient zero point |
< ± 0,2; (0...70 °C) |
Temperature coefficient span |
< ± 0,2; (0...70 °C) |
Response time |
< 9 |
Damping process value dAP |
0.01...30 |
Damping for the analogue output dAA |
0.01...30 |
Step response time analogue output |
28 |
Ambient temperature |
-20...80 |
Storage temperature |
-40...100 |
Protection |
IP 67; IP 69K |
EMC |
EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-5 Surge | 0,5/1 kV | EN 61000-4-6 HF conducted | 10 V |
|
Shock resistance |
DIN EN 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 | 10 g (10...2000 Hz) |
|
MTTF |
103 |
Pressure Equipment Directive |
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Weight |
565.2 |
Dimensions |
169 x 100 x 57 |
Materials |
stainless steel (316L/1.4404); PA; FKM; PTFE; viewing glass: laminated safety glass 4 mm |
Materials (wetted parts) |
Al2O3 (ceramics); FKM; stainless steel (316L/1.4404) |
Min. pressure cycles |
100 million |
Process connection |
threaded connection G 1/2 external thread |
Restrictor element integrated |
no (can be retrofitted) |
Display |
Display unit | 2 x LED, green | switching status | LED, yellow | switch points | LED ring, red | function display | alphanumeric display, red 4-digit | measured values | analogue display, 0...350° rotatable, pointer not visible when unit disconnected | measured values | alphanumeric display, red 4-digit |
|
With scale |
yes |
Extended display range (max.) |
|
Remarks |
switch point accuracy in the extended display range: 1.5 % of the span |
|
Pack quantity |
1 pcs. |
Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |