GF711S - Fail-safe inductive sensor
PRODUCENT CODE: GF711S
CATEGORY: Fail-safe inductive sensors
Producer: ifm electronic
450.64 PLN
(net)
2-3 days
3 pcs in stock
Stock levels are indicative. If the ordered goods are not in stock, we will inform you about the current delivery date.
Stock levels are indicative. If the ordered goods are not in stock, we will inform you about the current delivery date.
Fast shipping
Free delivery
from 1000 PLN (net)
Free delivery
from 1000 PLN (net)
Do you have questions about the product?
Ask an experienced consultant:
Ask an experienced consultant:
Description
GIFA4004-2PS/SIL2/V4A/US
- For ensuring machine safety
- Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
- No special actuator for electronic fail-safe sensors required
- Connection to safety PLC, safe AS-i modules or safe evaluation units
Technical data
| Product characteristics | |||||||||||||||||||
| Electrical design | PNP | ||||||||||||||||||
| Output function | 2 x OSSD (A1 and A2) | ||||||||||||||||||
| Enable zone | 0.5...4 | ||||||||||||||||||
| Housing | threaded type | ||||||||||||||||||
| Dimensions | M12 x 1 / L = 70 | ||||||||||||||||||
| Application | |||||||||||||||||||
| Special feature | Gold-plated contacts | ||||||||||||||||||
| Type of operation | continuous operation (maintenance-free) | ||||||||||||||||||
| Safety-related function | safe state when undamped | ||||||||||||||||||
| Application | Industrial applications / factory automation | ||||||||||||||||||
| Electrical data | |||||||||||||||||||
| Operating voltage | 19.2...30 DC | ||||||||||||||||||
| Rated insulation voltage | 30 | ||||||||||||||||||
| Current consumption | < 20 | ||||||||||||||||||
| Protection class | III | ||||||||||||||||||
| Reverse polarity protection | yes | ||||||||||||||||||
| Max. power-on delay time | 1000 | ||||||||||||||||||
| Outputs | |||||||||||||||||||
| Electrical design | PNP | ||||||||||||||||||
| Output function | 2 x OSSD (A1 and A2) | ||||||||||||||||||
| Max. voltage drop switching output DC | 2.5; (30 mA) | ||||||||||||||||||
| Permanent current rating of switching output DC | 100 | ||||||||||||||||||
| Output data | Interface type C class 1 | ||||||||||||||||||
| Output voltage at 24 V | compatible with EN 61131-2 inputs type 1, 2 | ||||||||||||||||||
| Short-circuit protection | yes | ||||||||||||||||||
| Overload protection | no | ||||||||||||||||||
| Max. capacitive load CL_max | 20 | ||||||||||||||||||
| Detection zone | |||||||||||||||||||
| Enable zone | 0.5...4 | ||||||||||||||||||
| Safe switch-off distance s(ar) | 6 | ||||||||||||||||||
| Response times | |||||||||||||||||||
| Response time to safety request | 1 | ||||||||||||||||||
| Response time when approaching the enable zone | 1 | ||||||||||||||||||
| Risk time (response time for safety-related faults) | 20 | ||||||||||||||||||
| Operating conditions | |||||||||||||||||||
| Applications | class C to EN 60654-1 weatherproof application | ||||||||||||||||||
| Ambient temperature | -25...70 | ||||||||||||||||||
| Note on ambient temperature |
|
||||||||||||||||||
| Ambient temperature | 10...40 | ||||||||||||||||||
| Note on ambient temperature |
|
||||||||||||||||||
| Rate of temperature change | 0.5 | ||||||||||||||||||
| Max. relative air humidity | briefly: 5...95 %; permanent: 5...70 % | ||||||||||||||||||
| Air pressure | 80...106 | ||||||||||||||||||
| Max. height above sea level | 2000 | ||||||||||||||||||
| Ionising radiation | not permissible | ||||||||||||||||||
| Salt spray | no | ||||||||||||||||||
| Protection | IP 65; IP 67 | ||||||||||||||||||
| Tests / approvals | |||||||||||||||||||
| EMC |
|
||||||||||||||||||
| Shock resistance |
|
||||||||||||||||||
| Vibration resistance |
|
||||||||||||||||||
| Safety classification | |||||||||||||||||||
| Complies with the requirements |
|
||||||||||||||||||
| Mission time TM | ≤ 175200 | ||||||||||||||||||
| Mission time TM (additional indication) |
|
||||||||||||||||||
| PFH | 1,0E-07 | ||||||||||||||||||
| Mechanical data | |||||||||||||||||||
| Weight | 105.5 | ||||||||||||||||||
| Housing | threaded type | ||||||||||||||||||
| Mounting | non-flush mountable | ||||||||||||||||||
| Dimensions | M12 x 1 / L = 70 | ||||||||||||||||||
| Thread designation | M12 x 1 | ||||||||||||||||||
| Materials | stainless steel (316L/1.4404); PBT | ||||||||||||||||||
| Displays / operating elements | |||||||||||||||||||
| Display |
|
||||||||||||||||||
| Accessories | |||||||||||||||||||
| Items supplied |
|
||||||||||||||||||
| Remarks | |||||||||||||||||||
| Remarks |
|
||||||||||||||||||
| Pack quantity | 1 pcs. | ||||||||||||||||||
| Electrical connection - plug | |||||||||||||||||||
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated | ||||||||||||||||||