URDK 09 - Ultrasonic retro-reflective sensors

URDK 09 - Ultrasonic retro-reflective sensors
Baumer


Models
Parameters
Description
Downloads
enlarge table
output currentvoltage drop Vdresidual rippleshort circuit protectionreverse polarity protectiontypehousing materialwidth / diameterheight / lengthdepthconnection typesoperating temperatureoutput circuitcurrent consumption max. (no load)scanning range sdreflector position Sdeadjusting range reflector (operating range)adjusting range reflector (limit range)repeat accuracytemperature driftresponse time tonrelease time toffsonic frequencyadjustmentalignment aidoutput indicatorvoltage supply range +Vsprotection class
URDK 09G8914< 100 mA< 2 VDC< 10 % VsyesyesrectangularPA 128,6 mm48,8 mm30,5 mmcable, 2 m0 ... +60 °Cpush-pull35 mA0 ... 200 mm60 ... 200 mm± 2,5 % Sde± 5 % Sde< 1,5 mm< 2 % Sde< 7 ms< 7 ms380 kHzTeach-intarget indication flashinggreen LED / red LED12 ... 30 VDCIP 67
URDK 09G8914/KS35A< 100 mA< 2 VDC< 10 % VsyesyesrectangularPA 128,6 mm48,8 mm30,5 mmflylead connector M8, L=200 mm0 ... +60 °Cpush-pull35 mA0 ... 200 mm60 ... 200 mm± 2,5 % Sde± 5 % Sde< 1,5 mm< 2 % Sde< 7 ms< 7 ms380 kHzTeach-intarget indication flashinggreen LED / red LED12 ... 30 VDCIP 67
X
URDK 09 - Ultrasonic retro-reflective sensors
output currentvoltage drop Vdresidual rippleshort circuit protectionreverse polarity protectiontypehousing materialwidth / diameterheight / lengthdepthconnection typesoperating temperatureoutput circuitcurrent consumption max. (no load)scanning range sdreflector position Sdeadjusting range reflector (operating range)adjusting range reflector (limit range)repeat accuracytemperature driftresponse time tonrelease time toffsonic frequencyadjustmentalignment aidoutput indicatorvoltage supply range +Vsprotection class
URDK 09G8914< 100 mA< 2 VDC< 10 % VsyesyesrectangularPA 128,6 mm48,8 mm30,5 mmcable, 2 m0 ... +60 °Cpush-pull35 mA0 ... 200 mm60 ... 200 mm± 2,5 % Sde± 5 % Sde< 1,5 mm< 2 % Sde< 7 ms< 7 ms380 kHzTeach-intarget indication flashinggreen LED / red LED12 ... 30 VDCIP 67
URDK 09G8914/KS35A< 100 mA< 2 VDC< 10 % VsyesyesrectangularPA 128,6 mm48,8 mm30,5 mmflylead connector M8, L=200 mm0 ... +60 °Cpush-pull35 mA0 ... 200 mm60 ... 200 mm± 2,5 % Sde± 5 % Sde< 1,5 mm< 2 % Sde< 7 ms< 7 ms380 kHzTeach-intarget indication flashinggreen LED / red LED12 ... 30 VDCIP 67
General data
scanning range sd 0 ... 200 mm
reflector position Sde 60 ... 200 mm
adjusting range reflector (operating range) ± 2,5 % Sde
adjusting range reflector (limit range) ± 5 % Sde
repeat accuracy < 1,5 mm
alignment aid target indication flashing
adjustment Teach-in
temperature drift < 2 % Sde
response time ton < 7 ms
release time toff < 7 ms
sonic frequency 380 kHz
output indicator green LED / red LED
Electrical data
voltage supply range +Vs 12 ... 30 VDC
current consumption max. 35 mA
output circuit push-pull
output current < 100 mA
voltage drop Vd < 2 VDC
residual ripple < 10 % Vs
short circuit protection yes
reverse polarity protection yes
Mechanical data
type rectangular
housing material PA 12
width / diameter 8,6 mm
height / length 48,8 mm
depth 30,5 mm
Ambient conditions
operating temperature 0 ... +60 °C
protection class IP 67
X

Pressure calculator


Type a known value and press Enter or click outside the edit box.

Pa - pascal
MPa - megapascal
kg/m2 - kilogram per square meter
kg/mm2 - kilogram per square millimeter
at - kilogram per square centimeter
atm - atmosphere
bar
PSI - pounds per square inch
mmHg - millimeters of mercury
mmH2O - millimeters of water
dyn/cm2 - dyne per square centimeter (baria)